Technical data flue gas analyzer BOSTON

Measure values

Measure Range

Resolution

Room temperature Pt 100

-10° ÷ 100°

0,1 C°

Fume temperature

0 ÷ 800 ° C

1° C

O2 - Oxygen

0÷21 % v/v

0,1 %

CO - Carbon monoxide

0÷4000 ppm

1 ppm

NO - Nitrogen oxide

0÷1000 ppm

1 ppm

SO2 Sulphur oxide

0÷2000 ppm

1 ppm

Draught / differential pressure UNI 10845 Bridge DMS

± 100 Pa
± 10 Pa

1.00 Pa
0.1 Pa







On request

Measure Range

Resolution

CO - room

0÷300 ppm

1 ppm

CO - %

1÷100000 ppm

10 ppm

Fume opacity

0÷9

1










.

Calculated Values

Measure Range

Resolution

CO2 – Carbon dioxide

0÷20% v/v

0.1%

Performance conforming to UNI 10389

0÷100

0.1%

Useful performance in condensation boilers
conforming to UNI 10389

> 100%

0.1%

Chimney loss conforming to UNI 10389

0÷100%

0.1%

Air excess conforming to UNI 10389

1÷50

0.01

Dew point conforming to UNI 10389

0÷100 °C

1°C











*